Precautions for Wafer type Connecting Dual Plate Check Valve to the Pipeline

When installing a wafer-type dual plate check valve in a pipeline, specific precautions must be observed due to its compact design and the way it interfaces with the piping system. Here are the key precautions:

  1. Correct Orientation:

Ensure that the flow direction matches the arrow indicated on the valve body. Installing the valve in the incorrect orientation can prevent it from functioning correctly and may cause damage.

  1. Centering the Valve:

Properly center the wafer-type valve between the flanges to prevent misalignment. Misalignment can lead to uneven sealing, potential leaks, and difficulty in operation.

  1. Gasket Placement:

Ensure the gaskets are correctly positioned and compatible with the valve and flange materials. They should be centered and not protruding into the valve flow area, as this could obstruct the valve plates and affect operation.

  1. Avoid Over-Tightening Bolts:

Tighten the flange bolts in a crisscross pattern to apply even pressure across the valve. Over-tightening can warp the valve body or damage the gaskets, leading to leaks or operational issues.

  1. Pipeline Support:

The pipeline should be properly supported on either side of the valve to avoid placing excessive weight or stress on the valve, which could affect its alignment and functionality.

  1. Check for Obstructions:

Inspect the pipeline for any debris or foreign objects before installation. Ensure that the valve plates can open and close freely without any obstructions.

  1. Correct Valve Sizing:

Verify that the valve is correctly sized for the specific flow rate and pressure conditions of the system. Using a valve that is too large or too small can lead to poor performance or damage.

  1. Even Flange Face Contact:

Ensure that the flange faces are clean, smooth, and parallel to ensure proper sealing. Uneven flange faces can cause leaks or improper seating of the valve.

  1. Avoiding Thermal and Mechanical Stress:

Avoid installing the valve in areas of the pipeline where it might be subjected to excessive mechanical stress, vibrations, or thermal expansion, which could lead to valve failure.

  1. Hydrostatic Testing:

After installation, conduct a hydrostatic test with the valve fully closed to check for leaks. Make sure the pressure applied during testing does not exceed the valve’s pressure rating.

  1. Proper Tools and Handling:

Use appropriate tools for handling and installing the wafer-type valve. Avoid using excessive force or improper tools, which could damage the valve body or internal components.

  1. Accessibility for Maintenance:

Install the valve in a location that allows for easy access for inspection and maintenance. Wafer-type valves often require periodic checks to ensure they are functioning correctly.

  1. Temperature and Pressure Considerations:

Ensure the valve materials are suitable for the operating temperature and pressure of the system. Avoid subjecting the valve to conditions that exceed its design specifications.

  1. Lubrication (if applicable):

Some wafer-type valves may require lubrication of the hinge pin or other components. Follow the manufacturer’s recommendations for any required lubrication.

By carefully following these precautions, you can ensure a secure, leak-free installation and reliable operation of the wafer-type dual plate check valve in your pipeline system.

Tianjin Tanghai Valve Co., Ltd. is a professional marine valve manufacturer, including butterfly valve, check valve, gate /Knife gate valve. We have certificates: CE, ISO, BV, DNV foundry and products approval. Now we have our own independent R & D, manufacturing, assembly and warehousing workshops; we have professional pre-sale and after-sale technical support and perfect services. Below is our wafer butterfly valve of marine valves,if you need to check more information, please click here:   https://www.tanghaivalve.com/wafer-type-butterfly-valve-th-btv-aw/

Please contact us if you need more support, please contact us freely: info@tanghaivalve.com.We are committed to “Build a top valve enterprise; Be a reliable partner!”Friends from all over the world are welcome to visit us for evaluation, guidance, and orders!